After getting a new roof installed, this property owner sent in some photos to get a second opinion. 

Bob, a property owner in Pennsylvania, recently had a TPO roof installed. When the project finished, they weren't quite sure if what they were looking at was normal. This is what they asked the AskARoofer experts: 

I had a TPO roof installed yesterday. It was adhered to a one inch iso board using LVOC bonding agent. There are quite a few bubbles on the roof. The roofer is telling me that this is normal and will flatten out. I’m not too sure and wanted to get some others opinions. Thank you.

Below is what one of our AskARoofer experts, John Kenney from Cotney Consulting, had to say about Bob's situation: 

Bob, based on the photos, this looks like the low-VOC bonding adhesive may have been applied a little heavily, or the membrane was installed before the adhesive had fully flashed off. That can trap solvent and cause the bubbles you are seeing. I cannot confirm the exact cause from photos alone, but I have seen this condition before.

The manufacturers treat low-VOC adhesives differently from some of their standard bonding adhesives. With certain low-VOC systems, their guidance is to let trapped solvent dissipate naturally for four to five days, then have the contractor return and thoroughly re-broom the membrane so it lies flat.

That makes your roofer’s explanation reasonable, but follow-through matters. I would expect the contractor to return after that period, re-broom the affected areas and verify that the membrane is properly bonded. I would not recommend trying to broom or repair it yourself.

This condition does not automatically mean the roof will leak, especially if the membrane and welded seams are sound. The main concern is whether the bubbles settle and bond after the solvent dissipates or whether some areas remain dry and unbonded.

I recommend documenting the roof with dated photos and confirming the exact adhesive used. If the bubbles remain after the contractor re-brooms the roof, ask the membrane manufacturer’s technical department to review the condition and confirm whether any additional work is needed or whether the warranty could be affected.

Continue the conversation in our Forum!

Have a question? AskARoofer.

Find your local roofing contractor in the AskARoofer™ Contractor Directory. 



Recommended For You


Comments

There are currently no comments here.

Leave a Reply

Commenting is only accessible to RCS users.

Have an account? Login to leave a comment!


Sign In
Westlake - Banner Ad - Roofing Elevated. Choices Unlimited. (AAR)
Westlake -  Ad - Roofing Elevated. Choices Unlimited. (AAR)
AskARoofer -  Ad - AAR Podcasts
Westlake -  Ad - US Tile Concrete & Clay Roofing (AAR)
AskARoofer -  Ad - AAR Find a Roofer
Tremco -  Ad - Is your rooftop safe?